Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the sgg domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/m_lab.dev.vanderbilt.edu/wp-includes/functions.php on line 6114
Instrumentation | The McLean Group Laboratory for Structural Mass Spectrometry | Vanderbilt University Skip to main content

Instrumentation

McLean Research Group Instrumentation

Trapped Ion Mobility-Mass Spectrometer (timsTOF Pro 2, Bruker)

  • Electrospray Ionization (ESI)
  • Thermally-Assisted Electrospray Ionization (VIP-HESI, Bruker)
  • Liquid Chromatography (1290, Agilent)

Traveling Wave Structures for Lossless Ion Manipulation (TWSLIM) Ion Mobility-Mass Spectrometer Platform

MOBIE CE (MOBILion Systems) coupled to a 6546 QTOF (Agilent Technologies)

  • Thermally-Assisted Electrospray Ionization (ESI, Jet Stream, Agilent)
  • Liquid Chromatography (1290, Agilent)

Drift Tube Ion Mobility-Mass Spectrometer (6560-A, patched to Revision C, Agilent Technologies)

  • Thermally-Assisted Electrospray Ionization (ESI, Jet Stream)
  • Alternate Drift Gas Kit and Switching Manifold
  • In-Source Ion Activation Lens
  • High Resolution Demultiplexing (HRdm)
  • Liquid Chromatography (1290, Agilent)

Traveling Wave Ion Mobility-Mass Spectrometer (Synapt G2-S, Waters Corporation)

  • Electrospray Ionization (ESI)
  • Desorption ESI (DESI, Prosolia prototype)
  • Matrix-Assisted Laser Desorption Ionization (MALDI, Waters)
  • Electron Transfer Dissociation (ETD)
  • Liquid Chromatography
  • Supercriticial Fluid Chromatography (SFC, UPC2, Waters)

 

Legacy Instrumentation:

Voyager STR-DE MALDI-MS

  • MALDI
  • Linear TOF

MALDI/ESI drift tube IM-MS (Ionwerks and McLean Research Group)

  • MALDI (MSI capable)
  • ESI
  • Periodic focusing drift tube (15 cm)

Synapt G2 (Waters)

  • Electrospray Ionization (ESI)
  • Matrix-Assisted Laser Desorption Ionization (MALDI)
  • Atmospheric Solids Analysis Probe (ASAP)
  • Electron Transfer Dissociation (ETD)
  • Surface-Induced Dissociation (SID)
  • Gas Chromatography (GC)
  • Gel Permeation Chromatography (GPC)

Octoplex IM-MS (McLean Research Group)

  • Incl. 8-channel electrospray ionization (ESI)

ACQUITY UPC2 (Waters)

  • Supercritical fluid chromatography (SFC)
  • Normal- and reversed-phase

In addition, we have access to the resources of the Center for Innovative Technology.